Everything about Insulated Glass totally explained
Insulated Glazing Unit or
Insulating Glass Unit (commonly referred to as
IGU) is a set of two or more lites of glass spaced apart and hermetically sealed to form a single glazed unit with an air space between each lite. Its most important function is to improve the thermal performance of glass when used in architectural applications. Another name often used in North America is
Sealed Insulating Glass (abbreviated
SIG). In the UK this is often called
Double glazing
The most commonly found IGUs are double glazed, for example made with two lites of glass and are therefore also referred to as "double glazing units" or "DGU" (especially in Europe) but IGUs with three lites or more, for example "triple glazing" are sometimes used for in very cold climates. Insulated glazing may be framed in a
sash or
frame or in a
curtain wall. IGUs are also commonly used for
replacement windows.
Insulating glass
IGU made of
glass is called insulated glass, which refers to heat insulation, not sound or electricity. A less accurate term is "insulating glass", since the glass itself has no insulative properties. It is the air space between the glass layers (lites) that provides the insulation.
It is important that the air remains as immobile as possible to prevent convection currents transferring heat across the insulating gap. This limits the thickness of the air gap used and is the reason for triple glazing.
The space between the lites may be filled with
air or an inert gas like
argon or
krypton which would provide better insulating performance. (Argon has a thermal conductivity 67% that of air.) Typically the spacer is filled with
desiccant to prevent
condensation and improve insulating performance. Less commonly, most of the air is removed, leaving a partial
vacuum, which drastically reduces heat transfer through
convection and
conduction. This is called evacuated glazing. Similar techniques are also used in
insulation products called
vacuum insulated panels.
Often the insulating quality is used in reference to
heat flow where the gap is the insulating medium. The gap is usually 12mm to 20mm thick. Within this range, the thickness does impact the insulating properties substantially, but smaller gaps have greater heat conduction through the air or other gas, and larger gaps allow more convection within the space leading to higher convective heat loss. A 16mm air gap is often considered the optimum thickness for air although this depends on many factors such as the size of the window, the temperature difference between the two panes and whether it's vertical.
In general, the more effective a fill gas is at its optimum thickness, the thinner the optimum thickness is. For example, the optimum thickness for krypton is lower than for argon, and lower for argon than for air. However, since it's difficult to determine whether the gas in an IGU has become mixed with air at manufacture time (or becomes mixed with air once installed), many designers prefer to use thicker gaps than would be optimum for the fill gas if it were pure. In some situations the insulation is in reference to
noise mitigation. In these circumstances a large gap improves the noise insulation quality or
Sound transmission class. Asymetric double glazing, using different thickness of glass rather than the conventional 4-12-4 symetrical systems, is more important than air gap thickness in improving the phonic insulation properties. This is often overlooked.
As of 2007,
argon is commonly used in insulated glazing as it's affordable.
Krypton, which is considerably more expensive, isn't generally used except to produce very thin double glazing units or relatively thin, or extremely high performance triple glazed units.
In principle,
xenon would be even more effective than krypton.
Insulated glass assemblies can't be cut to size in the field like plate glass but must be manufactured to the proper size in a shop equipped with special equipment.
The effectiveness of insulated glass can be expressed as an
R-value. The higher the R-value, the greater is its resistance to heat transfer.
Condensation inside units
The life of an IGU varies depending on the quality of materials and manufacture. Units typically last from 10 to 25 years. Condensation
between the layers of glass indicates that the perimeter seal has failed, and is usually irreplaceable.
Glass coatings
The heat and sound insulation of glazing may also be improved by the use of a film or coating applied to its surface. This film is typically made of polyester or metal, and may give the window a reflective appearance and
one-way mirror effect. It may be used on single-glazed windows as an alternative to insulated glazing, or on the outside layer of insulated glazing to further improve its effectiveness.
(External Link
) Such coatings may reduce fading of fabric and improve safety in case the glass breaks.
(External Link
). The Solar Heat Gain Co-efficient is a measure which expresses the proportion of incident solar thermal radiation that's transmitted by a window. Visible Transmittance describes the amount of visible light that can pass. Both of these can be independently altered by different coatings.
Tinted glass
Many of the films impart a color to the glass, typically blue, brown or gold, which may be used to enhance a building's architectural style
(External Link
). In automotive applications, where non-reflective and neutral-color tinted glazing is required, heat reflective properties are created using a nano-metre thick silver oxide layer within the windscreen
(External Link
). Insulating automotive glass is also called "athermic glass", "heat reflective glass" or "comfort glass".
Secondary glazing is sometimes used as a cheaper alternative. It consists of a layer of glazing placed retrofitted inside the window, to provide sound and heat insulation. Plastic sheet may be used for heat insulation, but may only last for one season.
(External Link
)
Low-emissivity coating
Low-emissivity (Low-E) glass has a thin coating, often of metal, on the glass within its airspace that reflects
thermal radiation or inhibits its emission reducing heat transfer through the glass. A basic low-e coating allows
solar radiation to pass through into a room. Thus, the coating helps to reduce heat loss but allows the room to be warmed by any sunshine. The low-e coating is usually on the inside pane of glass; if solar control is required then the outside pane of glass would have either a film or a body tint to reflect or absorb solar radiation. The principle of operation is similar to the
greenhouse effect in which short wavelength radiation is transmitted through the pane, but longer wavelength radiation is absorbed. However, low-e glass reflects the radiation rather than absorbing it, improving performance compared to the glass in a simple greenhouse.
Estimating Heat loss from Double Glazed Window
Estimating the rate of heat loss is essential in choosing which type of double glazed window to be used in a building to maintain desired thermal comfort.Relevant data and calculation from different calculations are listed below:
Required data:
- Thermal resistance of the glass used
- Physical properties of the gas used in between the gap (such as density, heat capacity and k value)
- Dimension of the double glazed glass
Table 1.1 Relevant correlations to calculate natural convection inside the window gap
| Condition |
Correlation |
| Further Information
Get more info on 'Insulated Glass'.
|
External Link Exchanges
Do you know how hard it is to get a link from a large encyclopaedia? Well we're different and will prove it. To get a link from us just add the following HTML to your site on a relevant page:
<a href="http://insulated_glazing.totallyexplained.com">Insulated glazing Totally Explained</a>
Then simply click through this link from your web page. Our crawlers will verify your link, extract the title of your web page and instantly add a link back to it. If you like you can remove the words Totally Explained and embed the link in article text.
As long as your link remains in place, we'll keep our link to you right here. Please play fair - our crawlers are watching. Your site must be closely related to this one's topic. Any kind of spamming, dubious practises or removing the link will result in your link from us being dropped and, potentially, your whole site being banned. |
|